PZTS (EZS)

Plain-language definition

Intruder and hold-up alarm system, formerly electronic security signalling.

3 November 2026updated

PZTS is the Czech abbreviation for an intruder and hold-up alarm system: equipment that watches a protected area, detects an intrusion or an emergency and raises an alarm. The older Czech name for the same thing is EZS (electronic security signalling).

PZTS and EZS: what is the difference

In substance they are the same type of system. The name PZTS is used by the Czech technical standards of the ČSN EN 50131 series. The word “hold-up” is a reminder that the system also summons help during an attack, for example with a panic button. The name EZS is still used in practice and in older contracts.

Key Components

  • Switchboard: A control unit that evaluates the states of individual sensors.
  • PIR detectors: Passive infrared sensors responding to temperature changes (human movement).
  • Magnetic contacts: They watch for the opening of doors and windows.
  • Emergency buttons: They allow the staff (e.g. at the reception) to immediately call for help in the event of an attack.

How an intruder alarm system works

  1. Detection: a sensor picks up movement, a door opening, breaking glass or a panic button being pressed.
  2. Evaluation: the control panel decides, according to its settings, whether this is an alarm and triggers a siren or a silent alarm.
  3. Transmission: a communicator sends the alarm to an alarm receiving centre (PCO), a mobile app or designated people.
  4. Response: someone verifies the alarm and, following the agreed procedure, goes to the site or calls the police.

Security grades

The ČSN EN 50131-1 standard defines four security grades by risk, from grade 1 for low risk to grade 4 for high risk. The grade sets how resistant the components and the alarm transmission must be. The required grade is often set by the insurer or the building design.

Intruder alarms and security staff

For effective protection, it is essential to agree in advance where the alarm goes, who verifies it and who physically responds on site. Without a follow-up procedure the alarm stays a siren on site and nobody verifies it.

Example and common misunderstanding

Common misconception

Confusing an intruder alarm (PZTS) with a fire alarm (EPS). PZTS reports an intrusion or an emergency, EPS reports a fire. They are separate systems with their own standards and operators.